Any questions?
We are happy to provide further information available.
Business: | +49 2452 962 400 |
---|---|
Industry: | +49 2452 962 777 |
End-consumers: | +49 2452 962 450 |
E-mail: | online-uk@trotec.com |
---|
Oil central heating ID 1200
The ardently sought-after professional solution for mobile heating applications with high capacity requirements.
Ranging from the robust stainless steel construction to the efficiency-optimized branded burner, the powerful high-pressure radial fan with high compression for long warm air hose distances and the practice-oriented transport equipment – it is not a coincidence that this central heating unit seems to be tailor-made for mobile heating applications in any location with a high heating demand and unavailable heater.
Whether for construction site heating, intervention in case of heating failures in residential and industrial buildings or for temperature control of large halls and marquees – the central oil heating unit ID 1200 was specifically designed for fully automatic, universal and unproblematic heating operation for demanding rentals at frequently changing locations.
All process and control elements are integrated behind lockable panels and thus protected against unauthorized access. Thanks to crane lifting lugs and integrated forklift pockets on all sides, transport, assembly and disassembly of this compact central heating unit can be realized quickly and economically.
Once commissioned, the ID 1200, running on a separate forced-air oil burner and equipped with an efficient fuel preheater as well as a heating oil filter protected from weather influences, is cold-resistant to ambient temperatures of as low as -20 °C.
A few practical benefits:
- Branded burner with high efficiency
- Single line system with automatic ventilation
- Large volume 300 W fuel pre-heating
- Photo cell flame monitoring
- High-performance heat exchanger
- Fully automatic operation with room air control
- High-pressure radial fan for long hose distances
- Cold-resistant to ambient temperatures of as low as -20 °C
- Lockable doors for operating elements and burner
- Built-in protected control box with operating hours counter
- Easy to service due to removable side panels
- Automatic fan with control for the rotation direction
- Built-in automatic circuit breaker
- Summer/winter selection switch for an optional ventilation without heating function
- Stainless steel skids for stationary use and transport
- Forklift receptacles
- Suitable for the fully automated use with external thermostat




Practical knowledge guidebook – heating know-how for professional users
Benefit from first-hand manufacturer know-how: On our guidebook pages we're providing you with some detailed information regarding the different types of heaters including a functional description, focuses of application and lots more.
Continue to the practical knowledge guidebook for professional heating
Shop
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 1.430.001.200 | |
Functional principle | ||
Method of heating indirect | ||
Method of heating direct | ||
Air flow rate | ||
Level Max. [m³/h] | 14,400 | |
Max. air pressure | ||
Level 1 [Pa] | 300 | |
Level 2 [Pa] | ||
Fan | ||
Radial | ||
axial | ||
Nominal heat input | ||
Level 1 [kW] | 200 | |
Level 2 [kW] | ||
Level Max. [kW] | 200 | |
Nominal heat output | ||
Level 1 [kW] | 185 | |
Level 1 [kcal] | 159,071 | |
Level 2 [kW] | ||
Level 2 [kcal] | ||
Level Max. [kW] | 185 | |
Level Max. [kcal] | 159,071 | |
Electrical values | ||
Mains connection | 400 V/50 Hz | |
Current consumption 1 [A] | 9 | |
Electric connection | ||
Connection plug | CEE 16 A, 5-pin | |
Operation | ||
Overheating protection | ||
Connection for external thermostat | ||
Internal thermostat | ||
Fuel feed | ||
Fuel feed | Danfoss pump | |
Fuel filter | ||
Available | ||
Suitable fuels | ||
Kerosene | ||
Diesel | ||
EL fuel oil | ||
Low-sulphur EL fuel oil | ||
Oil consumption | ||
Level Max. [l/h] | 21 | |
Hose connection | ||
Number of hoses | 1 | |
Diameter [mm] | 550 | |
Chimney connection | ||
Available | ||
Diameter [mm] | 200 | |
Sound values | ||
Distance 1 m [dB(A)] | 69 | |
Mobility | ||
Forklift | ||
Crane | ||
Dimensions | ||
Length (packaging excluded) [mm] | 2,400 | |
Width (packaging excluded) [mm] | 800 | |
Height (packaging excluded) [mm] | 1,300 | |
Weight | ||
(packaging excluded) [kg] | 490 |
Equipment, features and functions | ||
---|---|---|
Mobility | ||
Forklift | ||
Crane | ||
Carry/transport handle(s) | ||
Plastic wheels | ||
Rubber-tyred metal wheels |
standard equipment
optionally available
not available