Quality engineering "made in Germany" with scientifically proven effectiveness: The room air cleaner TAC V+
  1. Products & Services
  2. Products ‑ HighPerformance
  3. Air purification
  4. High-performance air purifier TAC V+

Room air cleaner: TAC V+ high-performance air purifier from Trotec

The TAC V+ is the proven, effective solution for the air purification of virus-carrying aerosol particles and bacteria from the room air

High-performance air purifier TAC V+ – air purification technology "made in Germany"

Effective virus filter system – scientifically proven effectiveness

The TAC V+ is one of the world’s first room air cleaner on the market that has been explicitly developed to filter out virus-carrying aerosols in interior spaces!

For this purpose, the air cleaner TAC V+ ensures a quick and highly effective reduction of virus-carrying aerosols from the room air and in this way effectively neutralizes the airborne corona infection risk, directly at the installation site.

Its virucidal effectiveness with regard to the neutralization of airborne viruses in interior spaces has been fully confirmed in several scientific studies for the TAC V+!

The air cleaner TAC V+, which is specially designed for silent operation combined with a large volumetric flow, quickly dilutes the virus-carrying aerosol accumulations with a high air volume and a high fan performance to a level that is unlikely to be infectious. It filters out 99.995 % of disease-causing viruses from the room air with its HEPA-H14 filter that is certified in compliance with EN 1822 and cyclically inactivates them by thermal decontamination of its heat-resistance special filter. In this way the high-performance air purifier TAC V+ effectively reduces the aerosol, viral and bacterial load in the room air.

Thanks to the exceptional cleaning performance of this high-performance air purifier, the risk of an indirect virus infection by airborne aerosol particles is substantially reduced!


The high-performance air purifier TAC V+ convinces by its efficiency-tested cleaning principle

In a continuous process, the room air that is contaminated with aerosol particles and infectious viruses is diluted and pushed towards the floor by a kind of “air roll effect”. The TAC V+ draws in large volumes of the contaminated air near the floor and already cleans them in the course of one air cycle with its H14 filter efficiency of 99.995 %, certified in compliance with EN 1822, reliably separating airborne germs.

The clean, virus-filtered clean air then flows back to the top of the room through the specially formed air outlet fins with a high fan performance. This air cycle continuously keeps the breathing air much cleaner, especially at head height, than without filtration. The filtered, blown-out air in this process is not only free from viruses but also free from pollen and respirable particulate matter that is often harmful (e.g. caused by traffic load).

With the TAC V+ you can decide for yourself which safety level is suited best for your demands

The device which can be configured via touch display can be easily programmed to match individual demands, making it possible to adapt the level of clean air filtering according to the individual situation. And thanks to the integrated boost function, targeted short and intensive filtration can be carried out, e.g. during break times or in the case of room changes, for quick separation with a maximum air volume.

From a scientific point of view, effective virus air purification requires at least 6 air circulations per hour and a HEPA filter not lower than class H14. Both the air cleaner and the H14 filter must therefore provide an air flow rate that is at least six times higher than the air volume of the room. In the case of a higher density of persons or a high level of physical activity, a higher circulation rate is recommended in order to ensure safety.

Large clean air capacity for effective air purification

Whether it is to be used for schools, offices, fitness studios or restaurants, the TAC V+ is ideally equipped for every requirement, since it features reserve capacities which allow for 12 or more air circulations per hour even in larger rooms. The number of air circulations required at the same time determines the safety level within the room.

TAC V+ with scientifically certified effectiveness!

Scientifically proven effectiveness: The TAC V+ offers what leading scientists require

As the only mobile air cleaner worldwide, the TAC V+ was specially designed for the purpose of virus filtration and, in this respect, has been tested for its effectiveness in the context of several scientific studies. Comprehensive studies confirm the virucidal effectiveness of the TAC V+ with its unparalleled HEPA-H14 filter system and therefore explicitly request this filter technology to ensure effective virus filtration. Learn more about the scientifically certified effectiveness of the TAC V+ ...


What makes the TAC V+ so unique and what makes it different from conventional air cleaners?

Trotec exclusive: Thermal decontamination and filter regeneration

The TAC V+ was designed specially for the purpose of virus filtration and in particular with a view to medium and large rooms such as school classrooms, office spaces or gastronomy spaces. Therefore this design not only provides for sufficiently dimensioned circulation rates, but additionally ensures a perfectly attuned ratio of filter performance, clean air volume and device size.

The specially constructed, fully encapsulated H14 high-temperature fins HEPA filter is a heat-resistant special design with an extremely high filter volume performance of class H14 (EN 1822), which can reliably filter out aerosols carrying viruses and bacteria, which is heated to approx. 100 °C for a short time and at regular intervals, a process that irreversibly denaturise the proteins of the viruses filtered out, which are relevant to the infectiousness, thus practically destroying those viruses. 100 °C for 100 % efficiency. Maximum safety and hygiene for protecting the health of your children, guests, customers and employees.

Scientific studies confirm the effectiveness of the unique filter decontamination and therefore explicitly request this filter technology to ensure effective virus and bacteria filtration: “To ensure that the room air cleaner always remains hygienically safe even in continuous operation, the H14 filter (EN 1822) should be heated to an approximate filter core temperature of 100  °C for about 15 minutes every day. This takes place in a freely adjustable and fully automatic fashion, e.g. outside office or teaching hours. Heating the filter to approx. 100 °C destroys the viruses in the filter and prevents the formation of bacteria, biofilm and fungi without harmful chemical additives or UV-C radiation.”

The advantages of this exclusive decontamination and regeneration technology from Trotec:

  • Separated viruses and bacteria are thermally destroyed in the filter. The exclusive added value with regard to safety and hygiene.
  • Thermal filter decontamination is freely programmable and is effected in a fully automatic fashion, e.g. outside business hours or school hours. Due to the short treatment duration and the low energy input , the room temperature does not increase.
  • The filter regeneration is a kind of self-cleaning function and guarantees a consistently high effectiveness of the special virus filter.
  • The thermal regeneration cycle effects the evaporation of the liquid portion of the aerosol particles and actively prevents the development of bacteria biofilm and filter odours – since your health is our top priority!
  • The lifetime of the filter is extended by its regeneration function, allowing for significantly reduced maintenance intervals and lower operating costs.
  • Thermal decontamination and filter regeneration at approx. 100 °C offer you more safety, hygiene and a long filter lifetime.

Why commercially available HEPA air cleaners are not sufficient for virus filtration in most cases

Large clean air capacity – high-performance filtration – filter decontamination – filter regeneration – noise level in the case of a large air volume – versatility

Well thought out to a detailed level, unparalleled in its entirety: With these 6 plus points, the TAC V+ – as is scientifically proven in several studies – ensures a technically effective and economically attractive solution to reduce the risk of infection by aerosols in closed rooms.

Stable design, flexible installation Virus protection on the spot


Large clean air capacity, high flow pressure and an optimum flow geometry

Only the TAC V+ has "the power to quickly dilute the room air"

Time is the most important factor when it comes to reducing the risk of an indirect infection. And we're talking about the shortest time possible for quickly and effectively diluting the infectious aerosol accumulations that are for example generated by a super-spreader, directly at their source. This requires large volumes of clean air and a high fan performance to establish an optimized flow geometry.

All this is provided by the TAC V+: With a large clean air volume, an optimum flow geometry and a flow pressure that is more than high enough, circulation is established in the room within a very short time, ensuring that all the contaminated room air is diluted and effectively filtered within only a few minutes.

Only circulation rates that are sufficiently high minimize the risk of infection, this is scientifically proven. Where the effective treatment of the risks of infection by aerosol particles is concerned, a high air circulation rate (at least a factor of 6 or even more, if possible) and therefore a large volume of cleaned air are indispensable, despite promises to the contrary made by other providers advertising single to threefold air change rates per hour as sufficient.

As is proven by scientific studies, effective virus filtration requires a sufficiently dimensioned volumetric flow so as to ensure that the air cleaner can provide for the number of air changes required as is guaranteed by the TAC V+. In this context, "air change" does not refer to a complete exchange of the air, but to the proportion of virus-filtered clean air that is supplied, relating to the room volume per hour.

FlowMatic ensures constant air circulation rates even with increasing filter pollution

In order to comply with the circulation rate required by the hygiene concept, a constant volumetric flow throughout the whole operating lifetime is indispensable. However, the filter elements of every air cleaner are successively clogged over time by coarse and fine dust (e.g. caused by traffic load). This leads to an increasing counter-pressure combined with a strongly decreasing air flow rate, inevitably reducing the level of protection envisaged.

With the innovative FlowMatic control of the TAC V+ You no longer have to worry about a decreasing volumetric flow or circulation rates that fall below the values required.

Just like with the cruise control of your car, the FlowMatic sensors capture the actual air flow rate values within the entire filter ladder and consecutively adapt the system performance dynamically. In this way, the air volume target value once preset remains constant in every situation! This not only increases the filter lifetime and system efficiency, but also guarantees compliance with the circulation rate required by the corresponding hygiene concept.

Air cleaners without a FlowMatic control are unlikely to constantly and reliably meet the requirements so as to comply with the circulation rate required.

High-performance filtration: H14 means maximum HEPA filter efficiency

The TAC V+ can "effectively separate" viruses

Heat-resistant H14 HEPA high-performance filter

Exclusively H14-HEPA high-performance filters complying with EN 1822 specifications (ISO 45H filter ISO 29463) like they are used in the TAC V+ are able to even filter the tiny virus-infected aerosol particles (0.1 - 0.2 µm) from the room air, and this at a percentage of 99.995 %. Therefore the filter efficiency of H14 HEPA filters complying with EN 1822 is 10 times higher than that of H13 HEPA filters with 99.95 %, as used in most air cleaners!

99.995 % or 99.95 %? This may not sound like a lot, but exactly these two decimal places make the big difference between H13 and H14 HEPA filters! Virus-carrying aerosol particles are extremely tiny. And "virus filters" are designed to "filter viruses". That's why the TAC V+ not only filters the large, but also the small-sized, highly infectious aerosols from the room air not even filtered out by FFP2 and FFP3 respiratory masks, which therefore don't offer genuine protection. Real safety is exclusively provided by an H14 HEPA filter (EN 1822)!

Scientific studies, however, qualify that a filter performance beneficial to the decay rate pursued can only be confirmed if the volume flow of the air cleaner and the flow speed in the particulate air filter are sufficiently attuned to one another by an adequately dimensioned filter surface, a property which at present cannot be achieved with any other mobile air cleaner than the TAC V+!

Thermal filter decontamination – your safety airbag

Unique technology – Trotec exclusive

The thermography image illustrates this: In the process of thermal decontamination the heat-resistant H14 virus filter of the TAC V+ is heated to approx. 100 °C, destroying all bound viruses and bacteria.
Fully encapsulated H14 high-temperature particulate air filter, equipped with heat-conducting metal lamellae

Only with the TAC V+ and TES 200 the special, fully encapsulated H14 high-temperature lamellae high-efficiency particulate air filter is treated thermally and heated to approx. 100 °C at regular intervals. Explicitly for this purpose, this filter has been developed and interspersed with special, heat conducting metal fins.

This thermal filter decontamination technology is available exclusively at Trotec and offers you several unique benefits at the same time! By heating the filters, the proteins of the viruses filtered out, which are relevant to the infectiousness, are denatured, and the viruses are practically destroyed. Therefore infectious viruses can no longer enter the ambient air from the filter, for example by improper handling Furthermore, bacteria, germs and other microorganisms are additionally destroyed.

All this means that 100 % employee protection can be ensured during operation and also when the filter is changed! You could say, it's the "virus airbag" that provides for more safety. It is there when you need it – and as long as nothing happens, you won't even notice it.

Scientific studies substantiate the mandatory prerequisite of thermal filter decontamination to ensure effective virus filtration. In fact, Professor Christian Kähler explicitly points out this mandatory provision in his study: "To ensure a maximum degree of hygiene and a longer lifetime in continuous operation, the H14 filter should be heated to approx. 100 °C every day for about 15 minutes, in order to destroy the viruses in the filter and prevent the formation of biofilms, bacteria and fungi without using harmful chemical additives or UV-C radiation."

Thermal filter regeneration – for optimum filter hygiene and a prolonged filter lifetime

No filter humidity, no filter mould or odour, and at the same time a much longer filter lifetime

Thermal filter decontamination and thermal filter regeneration

Aerosol separators and virus air cleaners take effect where many people are present in narrow spaces over a longer time and exhale larger quantities of aerosols. Aerosols, whether virus-carrying or not, for the greater part consist of micro droplets – pure water, that is. Customary H14 filters may be able to "catch" these humid aerosols, however, they also catch additional problems. Since the increasing humidity in the filter causes it to start fouling more quickly. As a result, the filter resistance increases, constantly reducing the clean air volume emitted and thus significantly reducing the filter lifetime. The fast fouling of filters at high loads of aerosols has been scientifically proven by field tests.

Moreover, the constantly high level of humidity favours the formation of filter mould or biofilms. Instead of eliminating a hazard, others may therefore be created. For example, a decreasing flow rate, shorter filter lifetimes and mould on the filter. But since the filter is heated to more than 100 °C at regular intervals, the ingress of moisture, fast sooting and filter mould are not a problem with the TAC V+. Since the humidity is fully discharged again in the course of the thermal regeneration cycle, not only drying the filter at regular intervals, but additionally regenerating it again via its self-cleaning function.

With this innovative procedure the filter resistance remains low and the clean air flow remains at a constantly high level for a considerably longer time. Consequently the lifetime is much longer than that of other filter systems without thermal regeneration and decontamination. This is also confirmed by current studies, which sum up as follows in the context of an examination of the TAC V+ and its H14 filter which complies with the specifications of EN 1822 (ISO 45H filter ISO 29463) and which features a self-cleaning function: "Therefore it is to be expected that this filter can have a lifetime of several years, depending on the load."

Low-noise: Hard to believe, hardly to be heard

The TAC V+ is an an air cleaning revolution of the silent kind

Sound protection hood to ensure silent operation

The task of qualified high-performance air purifiers is to make the utilization of interior spaces possible again – and not to make it more difficult! Nevertheless, without large volumes of clean air, the risk of infection cannot be minimized!

When aerosol particles are separated or viruses and bacteria are filtered out, high air circulation rates between 6 and 8 per hour are required, and in the medical sector even 12- to 15-fold air circulation rates per hour. Without these large air circulation rates, spontaneously occurring aerosol clouds cannot be reliably and quickly diluted and filtered out.

Therefore, even in smaller rooms of 45 m² you already need amounts of clean air from 700 m³ to 1,500 m³, which requires a fan with a correspondingly high ventilation power. In particular to establish an optimum air flow and air routing in the room. In addition to the flow geometry, filter efficiency and long filter lifetimes, however, an acceptable noise level, in spite of the large air volumes and the high fan performance, is desirable.

This is why one of the top priorities in the design of the TAC V+ was a low noise emission

For noise sensitive areas such as schools, offices or medical practices we recommend using the optional sound protection hood by means of which the sound level experienced subjectively can be again reduced by more than 50 %! In workshops, packing stations or discotheques, etc. the use of the sound protection hood usually is not required.

With an optional H14-Ultra-Highflow filter and an installed sound protection hood, the TAC V+ for example merely generates approx. 45 dB at level 3 with a clean air flow rate of 1,000 m³/h. For comparison: A customary laser printer already generates a sound level of approx. 50 dB during operation.

The TAC V+ is flexible, mobile and can be used everywhere at any time

The extremely stable, robust and scratch-resistant metal housing was specially designed for the use in environments where many people come together, work, play, learn or celebrate. This makes it possible to use the TAC V+ everywhere it's needed without any installation effort.

Flexible, mobile and modular – the exact number of TAC V+ devices required by the hygiene concept can be provided in each case. Variably adapted to the staff density, security level, type of application, background noise, room size and room geometry. The optionally available hose adapter makes it possible to also connect the TAC V+ to existing air distribution systems.

Where the effective control of infection risks due to aerosol particles is concerned, high circulation rates and therefore large and flexibly adjustable volumes of clean air are indispensable, despite promises to the contrary made by other providers who advertise single to threefold circulation rates per hour as sufficient.

To meet these requirements, the virus air cleaner not only has to be able to provide corresponding volumes of clean air, but it must also be flexibly placeable directly in potential hazard zones to ensure effective air routing. The TAC V+ is also optionally available in a tamper-proof version for the use in schools or daycare centres.

Scientifically proven: Only sufficiently high air change rates and proper positioning of the devices with respect to the air flow and routing provide a sufficient level of protection against an infection risk.


Well thought out to the detail, unparalleled in its entirety – the six benefits of the TAC V+ at a glance:

  1. Large clean air capacity: Up to 2,200 m³/h of virus-filtered clean air with a high flow pressure for optimum air circulation and high air circulation rates
  2. High-performance filtration: Fully encapsulated H14 lamellae high-temperature filter “made in Germany” with a flow-adapted filter surface for virus-filtered room air
  3. Thermal filter decontamination: 100 °C for 100 % inactivation of viruses, bacteria and other microorganisms, for maximum filter hygiene and longer lifetimes in continuous operation!
  1. Thermal filter regeneration: 100 °C for 100 % evaporation of the aerosols; self-cleaning function of the filter, low filter resistance, constantly high clean air volume, exceptionally long lifetime, no filter mould
  2. Background noise: The most silent high-performance air purifier in relation to the air flow rate / device size
  3. Versatility: Flexible, suitable for mobile and stationary application, “Plug & Play” for the connection to existing air distribution systems, modularly expandable
Other colour and model variants of the TAC V+ available
Also available as special model TAC V+ Dual for large halls

Apart from its standard colour yellow, the TAC V+ is also optionally available painted in basalt grey, white or bronze. More model variants and special solutions are available for you, like for example the TAC V+ in stainless steel version or the wall and ceiling model TAC V+ Dual for large halls.

Optional H14-Ultra-HighFlow filter – perfect for the economical air purification of larger rooms

Efficient H14-Ultra-HighFlow filter optionally available

In the case of larger rooms and a higher density of persons, the demand for high-performance air purifiers for effective virus filtration can quickly add up to several devices. By taking a look at our recommendation table you can see at a glance whether a TAC V+ is suitable for a specific room size as a function of the air circulation rate per hour requested by the hygiene concept.

When it comes to the virus filtration of larger rooms, with the optionally available H14-Ultra-HighFlow filter you'll be able to reliably ensure the required circulation rates in certified H14 clean air quality even by using fewer devices.

Compared to the standard H14 heat-resistant HEPA filter, the more powerful H14-Ultra-HighFlow filter allows for a 66 % higher clean air flow rate combined with a noise emission reduce by up to 8 % and an energy consumption that is lower by 30 %. (in relation to the clean air volume generated).

Air change recommendations for different rooms

At a glance: Convincing benefits of the high-performance air purifier TAC V+

High operational flexibility

"Plug & Play" for mobile and stationary applications. Also suitable for the connection to existing air distribution systems.

Significantly increased health protection

The high-performance air purifier TAC V+ from Trotec offers you, your employees, customers, clients, patients and pupils a high level of protection against indirect infection by aerosol particles. In addition to viruses and bacteria, also respirable and often harmful particulate matter (e.g. caused by road traffic) as well as pollen are reliably filtered from the room air.

A considerably higher level of safety – scientifically tested and recommended

The effectiveness of the room air purifier TAC V+ has been confirmed in several independent scientific studies carried out by leading institutes.

Large clean air capacity – high pressure

Up to 2,200 m³/h of clean air filtered free from viruses and bacteria by a high fan performance for optimum air circulation, air flow and frequent air circulation. Proper air flow and routing are an absolute must when you want to ensure a high degree of safety. In particular the high maximum air flow rate (boost mode) is ideally suited for quick separation (short and intense filtration) in break periods or in the case of room changes.

Effective high-performance filtration with the maximum HEPA filter class, certified in compliance with EN 1822

In the TAC V+, fully encapsulated H14 metal fin high-temperature filters "made in Germany" with flow-optimized hightech filter material are used, which are specially developed for Trotec. Each quality filter is tested and certified individually.

Optional: H14 Ultra-HighFlow filter

For 66 % more H14 air volume – with an energy consumption that is reduced by up to 40 % and a noise emission that is lower by up to 8 %.

FlowMatic control: Constant air circulation rates by constant volumetric flow for more safety

The sensor-supported FlowMatic control in the TAC V+ works like the cruise control in the car: Even when coarse and fine dust increasingly pollute the filter you don't have to be concerned about a decreasing air flow rate or about values falling below the required air changes.

The system performance is adapted continuously and dynamically, ensuring that the air volume target value once set is maintained at a constant level! For increased safety, longer filter lifetimes and a substantially higher system efficiency.

Unique: Thermal filter decontamination for more safety

Just like the airbag in the car – you hardly ever need it, but it's important that it's there! Reliable inactivation of the viruses and bacteria by heat (15 minutes at approx. 100 °C) provides an important added value where hygiene and safety are concerned. This is recommended by leading scientists to ensure safe continuous operation.

Thermal filter decontamination is freely programmable and is effected in a fully automatic fashion, e.g. outside business hours or school hours. Due to the short treatment duration and the low energy input (altogether approx. 1 kWh), the room temperature does not increase.

Unique: Thermal filter regeneration for more hygiene

Automatic self-cleaning of the filter to provide for a longer filter lifetime and to prevent bacteria, mould, biofilm and the formation of odours resulting therefrom. The process of filter regeneration takes place at approx. 100 °C in parallel to the thermal decontamination process and is recommended from a scientific point of view, since most bacteria and microorganisms are only inactivated at a temperature of approx. 100 °C. To ensure an improved filter hygiene and to prevent filter odour.

Fully automatic operation by flexible programming

Thanks to the fully programmable touch display, the TAC V+ can be adapted individually to your operating hours and rest periods, so that you no longer have to worry about anything.

Low noise emission

The most silent high-performance air purifier in relation to the air flow rate / device size.

Robust design for professional use

Extremely robust, stable and scratch-proof metal housing specially designed for operational environments where many people are staying, working, playing, learning or celebrating. Optionally also available as tamper-proof versions for schools, daycare centres, etc.


Thermal filter decontamination and thermal filter regeneration – exclusively available only at Trotec
Easy handling – programmable touch display
Easy handling – programmable touch display
Easy handling – programmable touch display
Easy handling – programmable touch display
Easy handling – programmable touch display
 
High fan performance for even, large-scale room air flushing with filtered clean air.
Mobile virus protection - can be quickly relocated by just one person


TAC V+ media library

The TAC V+ puts things into motion – an exceptional amount of virus-free clean air, satisfied customers and various media

In our media library for the TAC V+ you'll find some videos explaining the functional principle of the TAC V+ and its effective principle of air purification. In addition, we have compiled a large variety of different information videos describing the use of the TAC V+ in different fields of application like restaurants, supermarkets or fitness studios. Furthermore the TAC V+ media library will provide you with recommendation videos by satisfied users and with a selection of different media reports about the air cleaner TAC V+. Come and see for yourself ...

Even in times “without corona”, the TAC V+ will still be a precious investment as a universal guarantor of clean air

Virus filtration plus keeping the air free from particulate matter – completely pollution-free breathing air

Particulate matter pollution presents a permanent hazard to our respiratory organs. In addition, particulate matter is also suspected of being able to transport the coronavirus and of deteriorating the effects on health caused by a viral infection. Therefore it's all the more reassuring to the users of the virus air cleaner TAC V+ that it can be both at the same time: a demonstrably effective virus filter and basically a high-performance air cleaner. Today this provides you with a tried and tested air cleaner which neutralizes virus-carrying aerosol particles and bacteria in the room air – and at the same time you can benefit from maximum protection against harmful particulate matter pollution in your rooms – even for your life “without corona”. You can find more information on the fine dust problem here ...

Particulate matter is suspected of deteriorating the effects on health caused by a viral infection

Trotec solutions do not only allow you to generate clean and purified air, but also make the quality of the room air visible!

Triple indicator for healthy room air: Our BQ air quality measuring devices indicate all important values

Particle measuring device BQ30 for air quality monitoring

The Air quality monitor BQ30 should not be missing on any teacher's desk or in any open-plan office because this environmental monitoring station shows you the most important values for healthy room air at a glance: In addition to the current CO2 load and the prevailing climate data and the particulate matter pollution in particle size PM2.5 or PM10 are shown to you.

The CO2 pollution is an important indicator of required ventilation measures and the fine dust particle sizes determined also include pollen, a helpful feature to monitor the air quality for allergy sufferers! In rooms with a large number of persons, CO2 Traffic lights can serve as a means for rough-orientation to indicate whether the air quality is good or poor, as carbon dioxide (CO2) is a reliable indicator of an air change.

In addition to the BQ30 Trotec's range of products includes further professional particle counters such as the PC200 or the PC220. Our particle counters cannot only be used for inspecting the air quality, but to test filter systems as well, for example.

Note: Neither the degree of air pollution caused by particulate matter of the particle size PM2.5 nor the CO2 pollution in the room tells you anything about the infection risk! None of the two values are a measurand of the risk of infection, since there is no correlation between CO2 or PM2.5 concentration and viral load. Learn more about this subject area and several others with regard to virus filtration, filter classes, filter standards and other important operating figures – summarized in our air cleaner-FAQ for virus filtration ...


Buy

Room air purifier TAC V+ in White/black + sound insulation hood im Trotec Webshop zeigen

Room air purifier TAC V+ in White/black + sound insulation hood

The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.

Sie sparen: 277.22 €

4,194.00 € 3,916.78 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier TAC V+ in bronze/black + sound insulation hood im Trotec Webshop zeigen

Room air purifier TAC V+ in bronze/black + sound insulation hood

The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.

Sie sparen: 277.22 €

4,194.00 € 3,916.78 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier TAC V+ in grey/black + sound insulation hood im Trotec Webshop zeigen

Room air purifier TAC V+ in grey/black + sound insulation hood

The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.

Sie sparen: 277.22 €

4,194.00 € 3,916.78 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier TAC V+ + sound insulation hood im Trotec Webshop zeigen

Room air purifier TAC V+ + sound insulation hood

The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.

Sie sparen: 277.22 €

4,194.00 € 3,916.78 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier TAC V+ stainless steel + sound insulation hood im Trotec Webshop zeigen

Room air purifier TAC V+ stainless steel + sound insulation hood

The TAC V+ has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus "decontaminates" the filter 100%. Now with matching sound insulation hood.

Sie sparen: 316.88 €

4,794.00 € 4,477.12 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier M in basalt grey/black + sound insulation hood im Trotec Webshop zeigen

Room air purifier M in basalt grey/black + sound insulation hood

The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.

Sie sparen: 237.56 €

3,594.00 € 3,356.44 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier M in bronze/black +  sound insulation hood im Trotec Webshop zeigen

Room air purifier M in bronze/black + sound insulation hood

The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.

Sie sparen: 237.56 €

3,594.00 € 3,356.44 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier M in white/black + sound insulation hood im Trotec Webshop zeigen

Room air purifier M in white/black + sound insulation hood

The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.

Sie sparen: 237.56 €

3,594.00 € 3,356.44 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier M + sound insulation hood im Trotec Webshop zeigen

Room air purifier M + sound insulation hood

The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.

Sie sparen: 237.56 €

3,594.00 € 3,356.44 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Room air purifier TAC ECO + sound insulation hood im Trotec Webshop zeigen

Room air purifier TAC ECO + sound insulation hood

The high-performance air purifier TAC ECO ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.

Sie sparen: 160.97 €

3,173.64 € 3,012.67 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Technical data

Technical data
General information
  Article number 1.580.000.150
Dust class
  Staubklasse (gemäß DIN EN 1.822 (ISO 45H Filter ISO 29463) H14
  Staubklasse (gemäß DIN EN 779:2002) F7
Air flow rate
  Max. air volume flow [m³/h] 2,200
  Empfohlene Luftmenge HighFlow Filter für Filterklasse H14 ≤ [m³/h] 1,200
  Empfohlene Luftmenge HighFlow Filter für Filterklasse H13 ≤ [m³/h]] 1,800
  Empfohlene Luftmenge Ultra-HighFlow Filter für Filterklasse H14 ≤ [m³/h] 2,000
  Empfohlene Luftmenge Ultra-HighFlow Filter für Filterklasse H13 ≤ [m³/h] 2,200
Electrical values
  Mains connection 220 - 240 V/50 - 60 Hz
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Power consumption with thermal decontamination for 30 minutes [kW] 2.5
  Nominal current consumption [A] 11.3
  Recommended fusing [A] 13
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  mit Schallschutzhaube - Distance 1 m 40 - 64 dB(A)
  mit Schallschutzhaube und Ultra High Flow-Filter - Distance 1 m 38 - 62 dB(A)
Fan
  Radial
  axial
  stages 7
Dimensions
  Length (packaging excluded) [mm] 690
  Width (packaging excluded) [mm] 610
  Height (packaging excluded) [mm] 1,300
Weight
  (packaging excluded) [kg] 89
Equipment, features and functions
Equipment
  Thermal filter decontamination
  Thermal filter regeneration
  Touchscreen
  Gebrauchsbezogene, sensorgesteuerte Filterwechselanzeige des F7 Vorfilter
  Gebrauchsbezogene, sensorgesteuerte Filterwechselanzeige des H14 Hauptfilter
  FlowMatic-Steuerung
  Frei einstellbare Zeitschaltuhr für das Gerät
  Frei einstellbare Zeitschaltuhr für die Thermodekontamination
  Key lock
  sound protection hood
  Flowstop shutters
  Schlauchadapter
  Manipulationsschutz
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Hygienic areas (≥ 15 ACH) F7 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Carry/transport handle(s)
  Trestle rollers/ fixed castors
  Non-marking rubber wheels/rollers
  Foot
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame

 standard equipment

 optionally available

 not available

Accessories

Loading...

Alternative products

Loading...

Seminars

Downloads

Loading...

Video