Data logger DL200D
  1. Products & Services
  2. Measuring devices
  3. Climate
  4. Climate data loggers
  5. DL200 data logger
  6. DL200D

Data logger DL200D

A complete indoor meteorological station

DL200D data logger
DL200D data logger
DL200D data logger

In addition to environmental data the DL200D also captures the current air pressure values.

Due to real-time indication, long-term detection and logging of all measured values the DL200D is not only the perfect meteorological station for calibration laboratories.

Differences in air pressures can also be completely documented in all surroundings requiring permanent vacuum or overpressure conditions, e.g. in biology laboratories or isolation areas during restoration work.

Besides the standard anthracite colour, the data logger DL200D is optionally also available with a white or yellow housing.


Definition of measurement channel – How many measured values can be recorded?

All devices from the DL series are powerful multi-channel data loggers with which you can not only detect, but also record all of the compatible measured values (see technical specifications).

The term "measurement channel" is not used to mean the same as it is by some of our competitors – meaning the available sensors, but instead – the same as in analysis software – it means one individually selectable "recording track", i.e. the value which should be logged.

For each measured value and measured unit (channel group), one or more of the four following types of measured values can be recorded: current, minimum, maximum or average. Each of these four values represents a measurement channel.

The maximum amount of available measurement channels for each data logger is thus the amount of detectable channel groups (e.g. temperature in °C) multiplied by the four types of measured values.

In total, 20 of these measurement channels can be freely selected for logging and three for being displayed. 


Many measurement channels –
many possibilities...

The data logger can detect up to 32 measurement channel groups of the most varied sensor signals. Then, it can record an individually configurable composition of measured values from up to 20 separate measurement channels in freely selected intervals.

Due to the wide range of possible applications, the instruments are perfectly suited for monitoring the environment of buildings, controlling climate sensitive production processes and storage conditions or even providing evidence when required.

The devices are fitted with LAN and USB interfaces by default to offer a quick transfer of data.

Pro software for configuring
and managing measured data

Each measuring device comes with pro software, which can be used to simultaneously read as many data loggers as the user likes – and when using LAN, they don't even need to be nearby.

In addition to the comfortable option for administering and configuring various data loggers, the software can also be used to create reports or to export recorded measured data for archiving.

Real-time data compilation
in a network

All data loggers of the DL series can be assigned an individual IP address – even in decentralised measuring networks with many various data loggers – allowing both the transmission of measured data and also device configuration via LAN.


Pro software for configuring and managing measured data

Using the software included in the scope of delivery, all DL data loggers can conveniently be set up or configured for network operation. The measured data can simultaneously be read, analysed and exported by all data loggers – using LAN also from remote installation sites.

Now upgrade the standard software with the options MultiMeasure Studio Professional has to offer.

Since all DL models are fully compatible with this, the software is not only perfectly suited for the analysis of all measured data, but can also be used to calculate the dew point temperature or absolute humidity in retrospect, if it wasn't recorded already.

Finally one software for basically all measuring devices

Even owners of partially compatible or isolated measuring instruments can benefit from MultiMeasure Studio Professional: This software enables the analysis and administration of all measuring projects and customer data across multiple devices in a single application!

Using the unique report generating function you can create professional measurement reports in a trice:

Numerous boilerplate texts for building diagnostics, moisture measurement, leak detection and thermography are already included completely formulated.

All information about the "MultiMeasure Studio Professional" can be found here... 


A few practical benefits:

  • Maintenance-free measuring device "made in Germany"
  • Tamper-proof measured value detection and documentation
  • Perfect for measuring over a long period
  • Storage space for up to 3,200,000 measured values
  • Simultaneous recording by up to 20 separate measurement channels
  • Network function
  • Low energy consumption
  • Flexible power supply via battery or USB
  • Timer function, variable measurement intervals, alarm function for each measurement channel
  • Three-row LCD for measurement value display
  • Including pro software

Buy

Professional data logger DL200D Anthracite show in Trotec online shop

Professional data logger DL200D Anthracite

Professional data logger for long-term recording of climate data with USB and LAN interface, 16 MB of data storage and evaluation software included.

You save: 25.02 €

493.26 € 468.24 € incl. VAT Show net price (VAT not included)

buy

Technical data

Technical data
General information
  Article number 3.510.260.040
Air temperature [°C]
  Measuring principle | Air temperature NTC
  Min. measuring range | Air temperature [°C] -20
  Max. measuring range | Air temperature [°C] 50
  Accuracy ± | Air temperature [°C] 0.3
  Display resolution [°C] 0.1
Relative humidity
  Measuring principle | Relative humidity Capacitive
  Min. measuring range [% r.F.] 10
  Max. measuring range [% r.F.] 100
  Accuracy ± [% r.F.] 2
  Display resolution [% r.f.] 0.5
Air pressure
  measuring principle
  Measuring range [hPa] 300 – 1,300 (absolute air pressure)
  Accuracy ± [hPa] 0.5
  Display resolution [hPa] 0.1
CO2 concentration
  Measuring principle
  Measuring range [ppm]
  Display resolution [ppm]
  Accuracy
  Long-term stability [ppm/a]
Thermal element K
  Min. measuring range [°C]
  Max. measuring range | Thermal element K [°C]
  Accuracy Between -200 °C ... 0 °C [°C]
  Accuracy Between -200 °C ... 0 °C [°C] - Of measured value
  Accuracy Between 0 °C ... 1.200 °C [°C]
  Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value
  Resolution | Thermal element K [°C]
Thermal element J
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy -200 °C ... 0 °C [°C]
  Accuracy -200 °C ... 0 °C [°C] - Of measured value
  Accuracy Accuracy between 0 °C ... 1.200 °C [°C]
  Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value
  Resolution | Thermal element J [°C]
Thermal element S
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy Between -50 °C ... 0 °C [°C]
  Accuracy Between -50 °C ... 0 °C [°C] - Of measured value
  Accuracy 0 °C ... 1.700 °C [°C]
  Accuracy 0 °C ... 1.700 °C [°C] - Of measured value
  Resolution | Thermal element S [°C]
PT100
  Min measuring range [°C]
  Max. measuring range [°C]
  Accuracy [°C]
  Accuracy of the measured value ± | Pt100 [%]
  Resolution | Pt100 [°C]
Voltage input
  Min. measuring range [V]
  Max. measuring range [V]
  Accuracy ± [µV]
  Accuracy of the measured value - Voltage input ± [%]
  Resolution
Current measurement
  Min. measuring range in two-wire operation [mA]
  Max. measuring range in two-wire operation [mA]
  Min. measuring range in three-wire operation [mA]
  Max. measuring range in three-wire operation [mA]
  Accuracy ± [µA]
  Accuracy of the measured value ± | Current measurement [%]
  Resolution [µA]
  Approx. output load [Ω]
Display
  LCD
  Size [mm] 90 x 64
Memory organisation
  Sampling interval 10/30s, 1/10/12/15/30 min, 1/3/6/12/24h
  Saving interval 1/10/12/15/30, 1/3/6/12/24 h
  Memory 16 MB, 3,200,000 measured values
  Data logging Up to 20 measurement channels in parallel
  Available measurement channels 32
  Available channel groups 8
  Software TR, EN, EN, ES, FR
Interface
  LAN
  USB
  Plug socket
  BNC
  RS-485
  10-pin terminal
Housing design
  Plastics
Power supply
  Internal (battery) 4 x 1.5 V AA, operating time > 1 year (depending on sensor and configuration)
  External (USB)
  External (LAN, PoE model)
  Terminals for external power supply to supply the sensor
Dimensions
  Length (packaging excluded) [mm] 166
  Width (packaging excluded) [mm] 32
  Height (packaging excluded) [mm] 78
Weight
  (packaging excluded) [kg] 0.25
Standard scope of delivery
Standard scope of delivery
  Measuring device
  Battery(-ies)
  USB connection cable
  CD-ROM with Smartgraph PC software and operating manual
Ascertainable measured values and functions
Internal sensors
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Relative air pressure [hPa]
  Absolute air pressure [hPa]
  CO2 concentration [ppm]
External sensors
  CO2 concentration [ppm]
  Surface temperature [°C]
  Surface temperature [°F]
  Material temperature [°C]
  Material temperature [°F]
  Air temperature [°C]
  Air temperature [°F]
  Wood moisture [digits]
  Building moisture [digits]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Battery voltage [mV, V]
  Voltage [mV, V]
  Current [mA, A]
  Absolute air pressure [hPa, Pa]
  Relative air pressure [hPa, Pa]
  Differential pressure [Pa]
  Flow rate [m/s]
  Mixing ratio [g/kg dry air]
  Particle concentration [0.1 µm]
  Particle concentration [0.2 µm]
  Particle concentration [0.3 µm]
  Particle concentration [0.5 µm]
  Particle concentration [1 µm]
  Particle concentration [5]
  Particle concentration [10]
  Particle concentration [x µm]
  Particle concentration [y µm]
  Particle concentration [z µm]
  Unknown
  inactive
  Wet-bulb temperature [°C]
  Wet-bulb temperature [°F]
  Global radiation [W/m²]
  Daylight
  Amount of precipitation [l/m²]
  Wind speed [m/s]
  Wind direction
  Ground dampness
  Leaf wetness

 standard equipment

 optionally available

 not available