Any questions?
We are happy to provide further information available.
Business: | +49 2452 962 400 |
---|---|
Industry: | +49 2452 962 777 |
End-consumers: | +49 2452 962 450 |
E-mail: | online-uk@trotec.com |
---|
DL200H
The ideal solution for monitoring environmental factors
Using the two internal sensors of this data logger, simultaneously air temperature,
dew point and relative as well as absolute humidity can be measured and recorded.
That is why the DL200H is so well suited for monitoring the environment in buildings, computer centres, museums or storerooms and for controlling climate-sensitive processes during industrial production.



All data loggers are available as an option in addition to the standard colour
anthracite, with white or yellow housing.
A few practical benefits:
- Maintenance-free high quality measuring device „made in Germany"
- Tamper-proof measured value detection and documentation
- Perfect for measuring over a long period
- Storage for up to 3,200,000 measured values
- Simultaneous recording of up to 20 separate measurement channels
- Network function
- Low energy consumption
- Flexible power supply via batteries or USB
- Timer function, variable measurement intervals, alarm function for each measurement channel
- Three row LCD for measurement value display
- Including pro software
Shop

DL200H Professional Datalogger Anthracite
Professional data logger for long-term recording of climatic data with USB and LAN interface, 16 MB of data storage and evaluation software included.
Sie sparen: 16.68 €
328.84 €
312.16 €
inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.260.020 | |
Air temperature [°C] | ||
Measuring principle | NTC | |
Min. measuring range [°C] | -20 | |
Max. measuring range [°C] | 50 | |
Accuracy ± [°C] | 0.3 | |
Accuracy ± 0 °C - 40 °C [°C] | 0.3 | |
Display resolution [°C] | 0.1 | |
Relative humidity | ||
Measuring principle | Capacitive | |
Min. measuring range [% r.F.] | 10 | |
Max. measuring range [% r.F.] | 100 | |
Accuracy ± [% r.F.] | 2 | |
Display resolution [% r.f.] | 0.1 | |
Air pressure | ||
measuring principle | ||
Measuring range [hPa] | ||
Accuracy ± [hPa] | ||
Display resolution [hPa] | ||
CO2 concentration | ||
Measuring principle | ||
Measuring range [ppm] | ||
Display resolution [ppm] | ||
Accuracy | ||
Long-term stability [ppm/a] | ||
Thermal element K | ||
Min. measuring range [°C] | ||
Max. measuring range [°C] | ||
Accuracy Between -200 °C ... 0 °C [°C] | ||
Accuracy Between -200 °C ... 0 °C [°C] - Of measured value | ||
Accuracy Between 0 °C ... 1.200 °C [°C] | ||
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value | ||
Resolution [°C] | ||
Thermal element J | ||
Min. measuring range [°C] | ||
Max. measuring range [°C] | ||
Accuracy -200 °C ... 0 °C [°C] | ||
Accuracy -200 °C ... 0 °C [°C] - Of measured value | ||
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] | ||
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value | ||
Resolution [°C] | ||
Thermal element S | ||
Min. measuring range [°C] | ||
Max. measuring range [°C] | ||
Accuracy Between -50 °C ... 0 °C [°C] | ||
Accuracy Between -50 °C ... 0 °C [°C] - Of measured value | ||
Accuracy 0 °C ... 1.700 °C [°C] | ||
Accuracy 0 °C ... 1.700 °C [°C] - Of measured value | ||
Resolution [°C] | ||
PT100 | ||
Min measuring range [°C] | ||
Max. measuring range [°C] | ||
Accuracy [°C] | ||
Accuracy of the measured value ± [%] | ||
Resolution [°C] | ||
Voltage input | ||
Min. measuring range [V] | ||
Max. measuring range [V] | ||
Accuracy ± [µV] | ||
Accuracy of the measured value - Voltage input ± [%] | ||
Resolution | ||
Current measurement | ||
Min. measuring range in two-wire operation [mA] | ||
Max. measuring range in two-wire operation [mA] | ||
Min. measuring range in three-wire operation [mA] | ||
Max. measuring range in three-wire operation [mA] | ||
Accuracy ± [µA] | ||
Accuracy of the measured value ± [%] | ||
Resolution [µA] | ||
Approx. output load [Ω] | ||
Display | ||
LCD | ||
Size [mm] | 90 x 64 | |
Memory organisation | ||
Sampling interval | 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h | |
Saving interval | 1/10/12/15/30 min, 1/3/6/12/24 h | |
Memory | 16 MB, 3,200,000 measured values | |
Data logging | Up to 20 measurement channels in parallel | |
Available measurement channels | 24 | |
Available channel groups | 6 | |
Software | TR, EN, EN, ES, FR | |
Interface | ||
LAN | ||
USB | ||
Plug socket | ||
BNC | ||
RS-485 | ||
10-pin terminal | ||
Housing design | ||
Plastics | ||
Power supply | ||
Internal (battery) | 4 x 1.5V, AA, operating time > 1 year (depending on sensor and configuration) | |
External (LAN, PoE model) | ||
External (USB) | ||
Terminals for external power supply to supply the sensor | ||
Dimensions | ||
Length (packaging excluded) [mm] | 166 | |
Width (packaging excluded) [mm] | 32 | |
Height (packaging excluded) [mm] | 78 | |
Weight | ||
(packaging excluded) [kg] | 0.25 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Battery(-ies) | ||
USB connection cable | ||
CD-ROM with Smartgraph PC software and operating manual |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Air temperature [°C] | ||
Dew point temperature [°F] | ||
Relative humidity [%] | ||
Absolute humidity [g/m³] | ||
Dew point temperature [°C] | ||
Air temperature [°F] | ||
Relative air pressure [hPa] | ||
Absolute air pressure [hPa] | ||
CO2 concentration [ppm] | ||
External sensors | ||
CO2 concentration [ppm] | ||
Surface temperature [°C] | ||
Surface temperature [°F] | ||
Material temperature [°C] | ||
Material temperature [°F] | ||
Air temperature [°C] | ||
Air temperature [°F] | ||
Wood moisture [digits] | ||
Building moisture [digits] | ||
Relative humidity [%] | ||
Absolute humidity [g/m³] | ||
Dew point temperature [°C] | ||
Dew point temperature [°F] | ||
Battery voltage [mV, V] | ||
Voltage [mV, V] | ||
Current [mA, A] | ||
Absolute air pressure [hPa, Pa] | ||
Relative air pressure [hPa, Pa] | ||
Differential pressure [Pa] | ||
Flow rate [m/s] | ||
Mixing ratio [g/kg dry air] | ||
Particle concentration [0.1 µm] | ||
Particle concentration [0.2 µm] | ||
Particle concentration [0.3 µm] | ||
Particle concentration [0.5 µm] | ||
Particle concentration [1 µm] | ||
Particle concentration [5] | ||
Particle concentration [10] | ||
Particle concentration [x µm] | ||
Particle concentration [y µm] | ||
Particle concentration [z µm] | ||
Unknown | ||
inactive | ||
Wet-bulb temperature [°C] | ||
Wet-bulb temperature [°F] | ||
Global radiation [W/m²] | ||
Daylight | ||
Amount of precipitation [l/m²] | ||
Wind speed [m/s] | ||
Wind direction | ||
Ground dampness | ||
Leaf wetness |
standard equipment
optionally available
not available