Show all x TTK 500 x TTK 900 MP x Compact commercial dehumidifier TTK Qube x TTK 125 S x TTK 175 S x TTK 355 S x TTK 655 S x TTK 105 S x TTK 105 S with operating hours counter x TTK 140 S x TTK 170 S x TTK 350 S x TTK 650 S x TTK 75 ECO x TTK 165 ECO x TTK 166 ECO x TTK 170 ECO x TTK 171 ECO x TTK 380 ECO x TTK 570 ECO
TTK 500
TTK 900 MP
Compact commercial dehumidifier TTK Qube
TTK 125 S
TTK 175 S
TTK 355 S
TTK 655 S
TTK 105 S
TTK 105 S with operating hours counter
TTK 140 S
TTK 170 S
TTK 350 S
TTK 650 S
TTK 75 ECO
TTK 165 ECO
TTK 166 ECO
TTK 170 ECO
TTK 171 ECO
TTK 380 ECO
TTK 570 ECO

Technical data Equipment, features and...

2,612.05 € incl. VAT Show net price (VAT not included)

10.71 € incl. VAT per day

3,748.50 € incl. VAT Show net price (VAT not included)

You save: 391.76 €

1,219.75 € 827.99 € incl. VAT Show net price (VAT not included)

1,100.75 € incl. VAT Show net price (VAT not included)

7.14 € incl. VAT per day

1,350.65 € incl. VAT Show net price (VAT not included)

8.33 € incl. VAT per day

1,695.75 € incl. VAT Show net price (VAT not included)

2,623.95 € incl. VAT Show net price (VAT not included)

499.00 € incl. VAT Show net price (VAT not included)

Price on request

829.00 € incl. VAT Show net price (VAT not included)

949.00 € incl. VAT Show net price (VAT not included)

1,195.00 € incl. VAT Show net price (VAT not included)

1,895.00 € incl. VAT Show net price (VAT not included)

You save: 20.00 €

399.99 € 379.99 € incl. VAT Show net price (VAT not included)

599.99 € incl. VAT Show net price (VAT not included)

599.99 € incl. VAT Show net price (VAT not included)

You save: 49.00 €

678.99 € 629.99 € incl. VAT Show net price (VAT not included)

You save: 70.00 €

699.99 € 629.99 € incl. VAT Show net price (VAT not included)

1,194.99 € incl. VAT Show net price (VAT not included)

1,794.99 € incl. VAT Show net price (VAT not included)

Technical data
General information
Article number 1.120.000.410 1.120.000.802 1.120.000.117 1.120.000.124 1.120.000.157 1.120.000.163 1.120.000.174 1.120.000.109 1.120.000.108 1.120.000.141 1.120.000.155 1.120.000.160 1.120.000.171 1.120.001.110 1.120.001.115 1.120.001.116 1.120.001.120 1.120.001.125 1.120.001.160 1.120.001.180
Dehumidification performance
At 20 °C / 60 % RH [l/24h] 30 49 11 18 27 44 6.4 20 20 20 22 30 43
At 30 °C / 80 % RH [l/24h] 64 96 28 40 55 91 28.4 35 40 55 91 20 50 50 50 51 79 100
Max. [l/24h] 76 110 20 32 50 70 100 30 40 50 70 100 21 52 52 52 52 80 110
Air flow rate
Level 1 400 600
Level Max. 283 250 580 490 925 173 580 580 490 925 260 350 300 350 450 950 1,000
Level 2 850
Max. air volume flow [m³/h] 400 850
Recommended room size construction drying
470 800 150 225 450 750 112.5
190 320 60 90 180 300 45
Recommended room size dry keeping
940 1,600 110 300 450 900 1,470 230 350 450 450 1,470 110 230 230 230 230 1,000 1,100
380 640 45 120 180 360 590 90 140 180 180 590 45 90 90 90 90 400 440
Ambient conditions
Min. temperature range [°C] 5 3 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
Max. temperature range [°C] 35 40 35 32 32 32 32 32 32 32 32 32 32 32 35 32 30 32 32
Min. humidity range [%r.F.] 35 25 40 30 30
Min. humidity range [%RH] 50 50 50 50 30 50 50 50 50 30 30 10 30 20
Max. humidity range [%r.F.] 90 90 90 90 90
Max. humidity range [%RH] 90 90 90 90 90 90 90 90 90 90 90 95 90 90
Electrical values
Mains connection 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 230 V, 50 Hz 220 - 240 V, 50 Hz 230 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz 220 - 240 V, 50 Hz
Power input [kW] 1.6 2.098 0.362 0.5 0.6 1.4 2.1 0.5 0.6 0.6 1.4 2.1 0.35 0.82 0.95 0.82 0.65 0.95 1.95
Nominal current consumption [A] 7.3 9.8 1.7 2.3 2.8 6.1 9.5 2.1 2.7 2.8 6.1 9.5 1.5 3.7 4 3.7 2.7 4.2 8.1
Recommended fusing [A] 10 16 10 10 10 10 16 10 10 10 10 16 10 10 10 10 16 10 16
Required current starting phase [A] 7 25 16 25 15
Electric connection
Connection plug CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7 CEE 7/7
Cable length [m] 3 3 3 3 1.5 1.6 3 3 3
Compressor
Rotary piston compressor
refrigerant R454C R-454C R1234yf R290 R-410A R-454C R-454C R290 R290 R290 R-454C R-454C R290 R-410A R-410A R290 R290 R290 R-454C
Minimum room size [m²] 4 11 15 11 12 14
Amount of refrigerant [g] 650 900 140 150 150 650 1,050 125 150 150 650 1,050 100 230 200 230 230 300 1,000
GWP factor 146 146 4 3 3 146 146 3 3 3 146 146 3 3 3 3 3 3 146
CO2 equivalent [t] 0.095 0.13
CO2 equivalent 0.001 t 0.00045 t 0.00045 t 0.0949 t 0.15 t 0.00038 t 0.00045 t 0.00045 t 0.0949 t 0.15 t 0.0003 t 0.00069 t 0.0006 t 0.00069 t 0.00069 t 0.0009 t 0.146 t
Pressure suction side [MPa] 0.6 0.7 0.3 0.6 0.6 0.6 0.6 1.2 0.6 0.6 0.6 0.6 1 1 1 1 0.7 1 1
Pressure outlet side [MPa] 2.2 2.7 1.6 2.1 2.1 2.2 2.8 2.4 1.9 2.1 2.2 2.8 2.5 2.5 2.5 2.5 3.2 2.5 2.5
Max. permissible pressure [Mpa] 3 3 2.6 3 3 3 3 2.6 3 3 3 3 2.5 2.5 2.5 2.5 3.2 2.5 2.5
Water tank
Contents in [Litres] 6 6 6 5.2 6 6 6
Contents in [l] 4 5 7 5 5.5 9.5
Sound values
Distance 1 m [dB(A)] 64 53 52 52 54 56 50 52 52 54 56
Level 1 - Distance 1 m [dB(A)] 46 56 56 56 52 65 67
Distance 3 m [dB(A)] 58 59
Functions and features
Automatic operation
Indication of the current room humidity level
LED display
Current room temperature indication
Cable holder
Hygrostat connection
Continuous operation
Vario Dry operating mode
Operating button for draining residual water
Nonstop dehumidification (continuous operation)
Fan rundown function
Connection for external condensate drain
Comfort mode
Operating control lamp
Automatic switch-off
Automatic fault diagnosis system
Auto restart function
Memory function
Laundry drying function
LED display
Room temperature display
Display of the relative humidity level
Room temperature sensor
Dimensions
Length (packaging excluded) [mm] 438 500 315 375 390 390 620 250 400 540 530 616 295 495 480 495 525
Length (packaging included – handle excluded) [mm] 530 538
Width (packaging excluded) [mm] 470 565 382 345 380 380 515 342 400 490 500 511 305 455 450 455 490
Width (packaging included – handle excluded) [mm] 575 698
Height (packaging excluded) [mm] 870 960 340 603 643 725 858 517 605 963 965 1,022 562 840 655 900 900
Height (packaging included – handle excluded) [mm] 1,060 1,006
Weight
(packaging excluded) [kg] 52 69 16 26 35 39 55 14.5 27.5 32 39 52 20 31 30 31 40 50 64
Equipment, features and functions
Automatic defrost system
Hot gas
Air circulation / electronic
Electronic
Automatic dehumidification
Non-stop dehumidification
Hygrostat-controlled
Analogue hygrostat
Electronic hygrostat
Fan
axial
Radial
stages 1 2 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1
Condensate tank monitoring
Overflow protection with automatic switch-off
Container available
Filling level warning light to indicate a full water tank
Room air filter
Readily accessible
Ionizer selectable
Cleanable
Timer function
Switch-on time preselectable
Switch-off time can be preselected
Operating hours counter
Operating hours counter
Power meter, MID-compliant
Power meter
Mobility
Wheels
Feet
Adjustable bar handle
Carriage design
Carry/transport handle(s)
Protective bar
Swivel casters with parking brakes
Non-marking full-rubber wheels
Plastic wheels
Stand bar
Cable winder
Condensate drain
Hose connection possible
Hose included in the scope of delivery
Condensate pump
Recommended hose size [mm] 16 16 19 19 19 15 12.7 19 19 19 15.875 10 12 13 mm 12 11
Control panel
Membrane keys
Protective bar
Digital display
LC display
Control knobs
On / off switch
Touchscreen control panel
Shelf life
stackable
Housing design
Metal
Steel coated
Aluminium

 standard equipment

 optionally available

 not available