Advice for private customers: +49 2452 962-450

Advice for business customers: +49 2452 962-400

Mon – Fri: 8:00 – 17:00 (CET)

MID-compliant multiple socket outlet PV4-MID PS from Trotec
  1. Products & Services
  2. Products ‑ HighPerformance
  3. Accessories machines – high performance
  4. Multiple socket outlet PV4‑MID PS

Multiple socket outlet PV4‑MID PS

Easily handling the building site power supply in line with the regulations

Multiple socket outlet PV4-MID PS
With residual current device and MID-compliant* energy consumption meter
Easily handling the building site power supply in line with the regulations

Ideally equipped from the current consumption to the consumption measurement for invoicing

This multiple socket outlet that is equipped with PlugSafe is a quality product from original EU-manufacturing of robust design with which you're on the safe side in every respect when it comes to current consumption. The PV4-MID PS can be variably used for indoor and outdoor applications and facilitates the usage in accordance with MID, MessEG and MessEV.

The PV4-MID PS is intended for the operation at proper building-site power distributors and meets the requirements of BGI 608 with respect to switching devices and distributors for circuits with sockets. Please note that a BGI 608-compliant plug adapter must be used when operating the PV4-MID PS on construction or installation sites at a socket of the building's wiring with unknown protective measures.

Practice-oriented equipment

The extremely robust solid rubber housing with integrated carrying handle accommodates four safety sockets in accordance with VDE 0620-1. Furthermore, the PV4-MID PS is provided with a residual current device (RCD) and an MID-compliant* energy consumption meter – both secured beneath a transparent sealing cap that can be locked by means of an optional U-lock.

Product brochure Solutions for water damage restoration companies

PRODUCT BROCHURE

For water damage restorers: You can also find all relevant information about our insulation drying units in the product brochure. Download the PDF directly here.

To the PDF document

Legally required measurement and calibration obligations for water damage restoration and construction drying

In accordance with the German Measurement and Calibration Act (MessEG) and the appertaining German Measurement and Calibration Ordinance (MessEV) energy consumption meters used for billing purposes need to be calibrated or metrologically traceable to a corresponding device. MID*-compliant measuring devices meet these requirements.

In addition to the requirements of the European Measuring Instruments Directive certain consumer obligations are further applicable in Germany. For external measuring devices such as multiple socket outlets with integrated MID meter it must be ensured that no additional power consumers can be connected or the existing ones replaced by others whilst the device is in use.

The multiple socket outlet PV4-MID PS meets all requirements of MID, MessEG and MessEV

* What does MID-compliant mean?

MID-compliant counters correspond to the European Measuring Instruments Directive (MID) that defines the requirements for active power meters used for billing purposes. This for example also applies to the energy consumption measuring for recharging to insurance companies or customers. The former initial factory calibration is now replaced by the MID compliance, however, the devices have to be re-calibrated after a defined period of time – for instance after 8 years in case of electronic counters in Germany.

The multiple socket outlet PV4-MID PS meets all requirements of MID, MessEG and MessEV

Safely equipped – multiple socket outlet PV4-MID PS

The PV4-MID PS accommodates four safety sockets with self-closing spring-loaded flap lids and a max. power input of 3.6 kVA.
Four safety sockets with self-closing spring-loaded flap lids
All sockets are equipped with PlugSafe packing plates. PlugSafe equally allows for protection of the closed socket as well as protection with a plugged-in electricity consumer.
PlugSafe – socket protection suitable for sealing in accordance with the MessEG regulations
Both residual current device and MID-compliant* energy consumption meter are installed beneath a transparent sealing cap which can be protected against unauthorized access by means of an optional U-lock.
Residual current device and MID-compliant energy consumption meter
Both residual current device and MID-compliant* energy consumption meter are installed beneath a transparent sealing cap which can be protected against unauthorized access by means of an optional U-lock.
Residual current device and MID-compliant energy consumption meter
The resistant industrial housing with its IP44 type of protection is made of solid rubber and accommodates an oil- and UV-resistant connecting cable (H07RN-F).
Robust solid rubber housing with oil- and UV-resistant connecting cable (H07RN-F)

A few practical benefits:

  • For the proper use in compliance with the German Measurement and Calibration Act (MessEG)
    and the German Measurement and Calibration Ordinance (MessEV)
  • Ideal for rough operating conditions on ever-changing construction sites
  • PlugSafe – socket protection suitable for sealing in accordance with the MessEG regulations
  • Four safety sockets with self-closing hinged covers
  • Residual current circuit breaker and MID*-compliant energy consumption meter secured
    beneath a lockable sealing cap
  • Multiple socket outlet with hardwearing, solid rubber industrial housing
  • IP44 type of protection for use in construction sites, in wet rooms or outdoors
  • Oil- and UV-resistant cable (H07RN-F)

Buy

Technical data

Technical data
General information
  Article number 6.100.002.085
Electric connection
  Input voltage [V/Hz] 230 V AC, 50 Hz
  Power input [kVA] 3.6
  Max. preliminary fuse  [A] 16
  CEE 7/3 (Schuko socket type F)
  Number of sockets 4
  Connection plug CEE 7/3 (Schuko socket type F)
  Connection line 2 m, H07RN-F 3G2.5
Residual current device (RCD)
  Type (RCCB) Ttype A, pulse current sensitive
  Rated current RCCB [A] 25
  Rated residual current [A] 0.03
  Rated voltage RCCB 230 V AC, 50 Hz
  Rated diversity factor (RDF) 0.25
Active power meter
  Type (MID) MID-certified, non-resettable
  Indication 6 digit LCD
  Rated current [A] (MID) 0.25 A Imin, 45 A Imax, 5 A Iref
  Rated voltage MID 230 V AC, 50 Hz
  Accuracy class A
Housing design
  Rubber
  Standards DIN 49440-2, EN 50470-1, EN 50470-3, EN 61008-1, EN 61439-3, EN 62.262
  IP44
  Impact resistance IK10 (housing), IK8 (sockets)
Ambient conditions
  Operation - min. temperature [°C] -20
  Operation - max. temperature [°C] 45
  Operation - max. relative humidity (non-condensing) [%] 95
Dimensions
  Length (packaging excluded) [mm] 450
  Width (packaging excluded) [mm] 205
  Height (packaging excluded) [mm] 155
Weight
  (packaging excluded) [kg] 3

 standard equipment

 optionally available

 not available

Accessories

Loading...

Downloads

Loading...

Brochures

Loading...