BZ30 CO2 Air Quality Data Logger
For autonomous long-term recording of indoor air quality
Autonomous long-term recording of carbon dioxide concentration, room temperature and humidity
This CO2 air quality data logger is the ideal combination measuring device for architects, experts and every heating, ventilation and air conditioning engineer.
The BZ30 provides you with all functions and equipment features of the BZ25 and is further equipped with a large data memory for 50,000 measured values for the long-term recording of carbon dioxide concentrations, air temperature and humidity values in freely definable measuring intervals from 1 second to 12 hours.
The recorded data can be conveniently transferred to the connected PC via a fast USB connection and there analysed and logged using the analysis software included in the scope of delivery.
Owing to the integrated Li-Ion battery, the BZ30 is also suited for mobile application in addition to the stationary table installation.
The simultaneous recording of humidity and temperature values plus CO2 concentrations offers property managers or landlords optimal possibilities to monitor the ventilation habits.
Automatic baseline calibration
The expected CO2 fresh air value is about 400 ppm (0.04 %vol) nowadays. The device assumes this value to be the lowest limit value (baseline). Over several days, a special algorithm now permanently checks the lowest CO2 value measured of the sensor over a preconfigured time interval and slowly corrects every long-term drift determined by comparison with the expected fresh air value of 400 ppm (or 0.04%vol) CO2. In normal indoor applications, the carbon dioxide level usually decreases almost to outdoor air level at some point during one week. By recording the values over a period of 8 days and then comparing the lowest value to the 400 pm point, the device determines whether or not it needs to adjust the zero point. This takes place fully automatically. The algorithm therefore makes use of the fact that the CO2 content in buildings and rooms regularly stabilises at a minimum for a certain period of time when they are not occupied. In rooms that are continuously occupied or where there is a constantly increased CO2 concentration (e.g. in greenhouses), this principle of automatic balancing therefore does not work.
BZ30 – Special equipment features
Accurate and permanently stable NDIR measurement of carbon dioxide concentrations in the room air
Certified safety - factory calibration of measuring devices directly from the manufacturer
As one of the leading full-range suppliers of measuring equipment for building diagnostics and environmental technology, Trotec offers you the opportunity to have all measuring devices calibrated, maintained and repaired from a single source. With a calibrated measuring device, you avoid inaccurate measurement results and can reliably protect yourself against possible recourse claims. So play it safe and use our calibration service for your Trotec measuring devices: In our in-house laboratory, we calibrate according to the factory standard to firmly defined measuring ranges and points. Optionally, the calibration points can also be individually defined within the specified calibration range.
A few practical benefits:
- Accurate and permanently stable NDIR measurement of carbon dioxide concentrations in the room air
- Simultaneous display of CO2 values, room temperature, humidity, date and time
- Minimum and maximum value function for CO2, air temperature and humidity
- Automatic Baseline Calibration
- Carbon dioxide alarm function with acoustic alarm signal for freely definable limit values
- Additional symbolic CO2 indicator display
- Large backlit display with easily legible measured value indication
- Autonomous long-term recording of carbon dioxide concentration, room temperature and humidity
- Storage for 50,000 measured values
- Freely definable saving interval from 1 second to 12 hours
- USB interface for measuring data transfer
- Free standing or wall mounted
- PC analysis software
Shop
CO2-Luftqualitätsdatenlogger BZ30
You save: 100.00 €
199.99 €
99.99 €
incl. VAT
Show net price (VAT not included)
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.205.015 | |
Air temperature [°C] | ||
Measuring principle | Air temperature | NTC | |
Min. measuring range | Air temperature [°C] | -5 | |
Max. measuring range | Air temperature [°C] | 50 | |
Display resolution [°C] | 0.1 | |
Accuracy ± | Air temperature [°C] | 1 | |
Air temperature [°F] | ||
Min. measuring range | Air temperature [°F] | 23 | |
Max. measuring range | Air temperature [°F] | 122 | |
Display resolution [°F] | 0.1 | |
Accuracy ± | Air temperature [°F] | 1.8 | |
Relative humidity | ||
Min. measuring range [% RH] | 0.1 | |
Max. measuring range [% RH] | 99.9 | |
Display resolution [% RH] | 0.1 | |
Accuracy [% RH] | 5 | |
CO2 concentration | ||
Measuring principle | NDIR | |
Min. measuring range | Carbon dioxide [ppm] | 0 | |
Max. measuring range | Carbon dioxide [ppm] | 9,999 | |
Accuracy | Carbon dioxide [ppm] | 75 | |
Accuracy | Carbon dioxide [%] | 5 | |
Accuracy | ±75 ppm / ±5 % | |
Display resolution [ppm] | 1 | |
Display | ||
LCD | ||
Memory organisation | ||
Sampling interval | > 1 s | |
Saving interval | > 1 s | |
Memory | 50,000 Measured values | |
Interface | ||
USB | ||
Device control | ||
Push buttons | ||
Housing design | ||
Plastics | ||
Power supply | ||
Internal (battery) | 1 x 3.7 V Li-ion battery or 230 V power adapter | |
Connection plug | Eurostecker EN50075 | |
Dimensions | ||
Length (packaging excluded) [mm] | 90 | |
Width (packaging excluded) [mm] | 110 | |
Height (packaging excluded) [mm] | 98 | |
Weight | ||
(packaging excluded) [kg] | 0.245 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Battery(-ies) | ||
Power adapter | ||
USB connection cable | ||
PC software (download) | ||
Operating manual |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Relative humidity [%] | ||
CO2 concentration [ppm] | ||
Air temperature [°C] | ||
Air temperature [°F] | ||
Functions and features | ||
Minimum value display | ||
Maximum value display | ||
Measured value hold function | ||
Automatic Baseline Calibration | ||
Switching function °C/°F | ||
Backlit display | ||
CO2acoustic alarm function | ||
CO2sensor | ||
Feel-good indication | ||
Date | ||
Time |
standard equipment
optionally available
not available