Heat stress measuring device TC100
Climatic workplace assessments made easy: quick, precise and conforming to standards
The TC100 is a multifunctional diagnostic device for professional climate checks and quickly determines the WBGT index, e.g. for the assessment of thermally stressed workplaces.
By means of a special function direct sunlight can either be disregarded or taken into account for adjusted measurements in interior spaces or outdoor areas. You can also define an individual WBGT alarm threshold. There will be an immediate acoustic indication when this value is exceeded.
Moreover, the TC100 is able to determine virtually any measured variable relevant for climatic comfort.
Be it air temperature, humidity, radiant heat, wet-bulb and dew point temperature or air pressure – all these parameters can be called up in real time, indicated on the backlit display as held, minimum, maximum or average value and up to a capacity of 99 measured values saved directly on the TC100.
For long-term measurements the TC100 can also be attached to a tripod. In addition, the measuring device houses both a mini USB port and a barrel-type 9 V coaxial power socket. These ports permit a continuous mains operation as alternative to the battery-powered application. Also, to ensure a mobile power supply via the mini USB port, the TC100 may be connected to a powerbank.
No other stand-alone hand-held WBGT measuring device on the market can detect a greater number of different measured variables:
- Climate index (WBGT) for indoor and outdoor areas
- Radiant heat (black globe)
- Heat index (HI)
- Air temperature
- Relative humidity
- Dew point temperature
- Wet-bulb temperature
- Air pressure
Standard-compliant measurement of the WBGT index
Persons working at installations or in environments with a high energy output or thermal radiation are greatly exposed to the risk of heat stress.
Amongst other measures exposure and rest periods adapted to the respective load level have been stipulated for the health protection of these employees.
The thermal load intensity is calculated from various climatic factors. The internationally standardized term for this climate index is WBGT index (wet-bulb globe temperature).
This index, originally developed by the US military for boot camps, is now defined in DIN EN 27243 and i.a. serves for the development of guidelines regarding work breaks and restrictions for thermally stressed workplaces.
Other than for the WBGT, the TC100 can also be used to determine the heat index – also referred to as humidex – which describes the combined effect of humidity, temperature and radiant heat on the human body.
Since the physical performance decreases at increasingly high temperatures, WBGT and heat index are more and more often used to aid the decision-making process of professional athletes or on sports events.
All climate measuring devices in direct comparison:
To find the climate measuring device which exactly meets your requirements, please consult the concise overview of all climate measuring devices from Trotec, which we're providing to you here so that you can compare them directly to each other.
Models which you do not wish to include in your comparison can be easily dismissed with only one click.
A few practical benefits:
- For the assessment of heat stress or standardized thermal comfort measurements at the workplace according to ISO 7243, ISO 7726 and DIN 33403
- Fast response time
- Zero adjustment function
- Offset adjustment for radiant heat, air temperature and humidity
- Data hold, MAX/MIN and alarm function
- Data memory for 99 measured values
- Display illumination
- ¼ inch threading for tripod connection
- In addition to battery operation also permits mains operation for non-stop measurements
- Energy-saving automatic switch-off
- Incl. calibration certificate
Buy
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.007.010 | |
Air temperature [°C] | ||
Min. measuring range | Air temperature [°C] | 0 | |
Max. measuring range | Air temperature [°C] | 50 | |
Resolution [°C] | 0.1 | |
Accuracy ± | Air temperature [°C] | 0.6 | |
Air temperature [°F] | ||
Min. measuring range | Air temperature [°F] | 32 | |
Max. measuring range | Air temperature [°F] | 122 | |
Relative humidity (%) | ||
Min. measuring range | Relative humidity [%] | 0 | |
Max. measuring range | Relative humidity [%] | 99.9 | |
Accuracy 0 % - 10 % [%] | 5 | |
Accuracy 10 % - 70 % [%] | 3 | |
Accuracy 70 % - 99.9 % [%] | 5 | |
Black globe temperature (°C) | ||
Min. measuring range | black globe temperature [°C] | 0 | |
Max. measuring range | black globe temperature [°C] | 80 | |
Accuracy (20°C-50°C) ± | black globe temperature [°C] | 0.6 | |
Accuracy (<20°C / >50°C) ± | black globe temperature [°C] | 1 | |
Apparent temperature (WBGT) [°C] | ||
Min. accuracy indoors | apparent temperature (WBGT) [°C] | 15 | |
Max. accuracy indoors | apparent temperature (WBGT) [°C] | 59 | |
Accuracy indoors [°C] ± | apparent temperature (WBGT) | ±1 | |
Min. accuracy outdoors | apparent temperature (WBGT) [°C] | 15 | |
Max. accuracy outdoors | apparent temperature (WBGT) [°C] | 56 | |
Accuracy outdoors [°C] ± | apparent temperature (WBGT) | ±1.5 | |
Air pressure [hPa] | ||
Min. measuring range [hpa] | 300 | |
Max. measuring range [hpa] | 1,100 | |
Accuracy ± [hpa] | 1.5 | |
Resolution | air pressure [hpa] | 0.1 | |
Display | ||
LCD | ||
Monochrome | ||
Device control | ||
Push buttons | ||
Housing design | ||
Plastics | ||
Power supply | ||
Internal (battery) – 4 x AAA 1.5 V | ||
Via mains current - 9V AC/DC | ||
Internal (battery) | 4 x 1.5 V, AAA | |
Ambient conditions | ||
Operation - min. temperature [°C] | 0 | |
Operation - max. temperature [°C] | 50 | |
Storage - min. temperature [°C] | -20 | |
Storage - max. temperature [°C] | 50 | |
Storage - max. relative humidity (non-condensing) [%] | 90 | |
Dimensions | ||
Length (packaging excluded) [mm] | 162 | |
Width (packaging excluded) [mm] | 58 | |
Height (packaging excluded) [mm] | 32 | |
Weight | ||
(packaging excluded) [kg] | 0.215 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Calibration certificate | ||
Storage case | ||
Operating manual |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Air temperature [°C] | ||
Air temperature [°F] | ||
Relative humidity [%] | ||
Black globe temperature [°C] | ||
WBGT | ||
Air pressure | ||
Dew point temperature [°C] | ||
Dew point temperature [°F] | ||
Functions and features | ||
Heat index (HI) | ||
Apparent temperature (WBGT) | ||
Wet-bulb temperature | ||
Switching function °C/°F | ||
Switching function hPa/inHG/mmHG | ||
Minimum value display | ||
Maximum value display | ||
Average value display | ||
Measured value hold function | ||
Alarm function for and apparent temperature (WBGT) | ||
Automatic switch-off | ||
Display illumination |
standard equipment
optionally available
not available